======================================================================== *** Basic Information *** ======================================================================== [Create date] 2013/06/28 ------------------------------------------------------------------------ [Program Name] Scanner ------------------------------------------------------------------------ [Version] 01.25 ------------------------------------------------------------------------ [PCB No.] ------------------------------------------------------------------------ [Interchangeability] X / O ------------------------------------------------------------------------ [Other Firmware Requirements] None ------------------------------------------------------------------------ [PCB Requirements] None ------------------------------------------------------------------------ [Software category] Normal Release ------------------------------------------------------------------------ [Release category] Normal Release ------------------------------------------------------------------------ [Program category] Firmware ------------------------------------------------------------------------ Exported to(language) GEN(all) [Firmware No.] D0255570K [File Information] File Name D0255570K.fwu File Type Module for Service Size 1.20 MB ( 1254840 byte ) [File Information] File Name D0255570K.rfu File Type Module for Remote Upgrade Size 1.20 MB ( 1261824 byte ) ------------------------------------------------------------------------ [Production reflection] 2013/3 ------------------------------------------------------------------------ ======================================================================== *** Note *** ======================================================================== [Note] ------------------------------------------------------------------------ ======================================================================== *** Important Notes *** ======================================================================== [Important Notes] ------------------------------------------------------------------------ ======================================================================== *** Modification History *** ======================================================================== [Modifications made:] Symptom corrected: WSD scanning a color jpg results in any subsequently scanned BW TIFFs being output as PDFs. ------------------------------------------------------------------------ [Modification history] ---------------------------------------- Version 01.24 Other changes: WSD Scanner (Push Type) now supports Windows 7/Windows 2008 Server R2. Notice: Due to Windows 7/WIndows 2008 Server R2 spec changes, WSD Scanner (Push Type) jobs that are in-progress can no longer be manually cancelled from the PC side. Symptom corrected: 1. A scan configured to output a Multi-page TIFF might have actually output a PDF. This only occurred if both of the following conditions were met: - Scanner operation panel > Send Settings > Compression (Gray Scale/Full Color) > OFF - Scanner operation panel > Scan Settings > Scan Type > Auto Color Select 2. The MFP operation panel might go black and not return until the power is cycled. This only occurred if User Authentication was enabled or the MFP had a Device Accounting Unit such as a coin collector or charge card reader. ---------------------------------------- Version 01.23 Symptom corrected: 1. Scan to NCP fails if all of the following conditions met: - The destination is specified using the IP address. - The Novell server and the device are in different subnets. - The subnet routers filter SLP multicasts. Note: Requires System firmware (version 1.22 or later) and Scanner firmware (version 01.23 or later). 2. Scan to NCP fails or takes long time to complete if the IPX protocol is used and there are more than 2 Novell Directory Services (NDS) servers in the netwok hierarchy. Note: Requires System firmware (version 1.22 or later) and Scanner firmware (version 01.23 or later). ---------------------------------------- Version 01.22 Other changes: 1. Multiple stored jobs submitted for printing simultaneously will now be recorded individually in the Job log instead of only the first job being recorded. This change only applies to non-print jobs that have been stored. Prior to this change, the printing of stored print jobs were already recorded individually in the Job log. Note: Requires the following firmware versions (or later): System (version 1.21), Websys (version 1.10), Scanner (version 01.22), WebUapl (version 1.08), and either of NFA (version 1.03). ---------------------------------------- Version 01.21 Symptom corrected: 1. Job log CSV file contains the wrong "User Entry ID" for scanner jobs that were sent from the document server. This only occurred using either UserCode Authentication or Basic Authentication. 2. The Job log displayed by WSDM contains the wrong "User Code/User Name", "User Entry ID" and "User display name" for scanner jobs that were sent from the document server. This only occurred using either UserCode Authentication or Basic Authentication. ---------------------------------------- Version 01.20 Symptom corrected: 1. Some characters are printed out incorrectly on the Scanner Sending History on machines for certain regions. ---------------------------------------- Version 01.19 Symptom corrected: 1. The scanner will stall "Updating the destination List. Please wait..." will be displayed on the operation panel. This occurs if the device's address book is updated via ScanRouter while the device is in Sleep Mode. ---------------------------------------- Version 01.17 1st Mass production